Carbon Monoxide Sensor 4-Electrode

Model: CO-B4

Alphasense 4-Electrode gas sensors operate using proven fuel cell technology.

The B4 series (4-electrode sensors) provides OEMs with reliable sensors for use in a number of high volume applications and especially Air Quality Networks where very low parts per billion (ppb) detection levels are required.


Strong signal levels combined with low zero current allows resolution to < 10 (ppb) and a wide operating range. The sensors are suitable for use in fixed installation sensing heads, portable safety instruments, urban/indoor air monitoring and stack gas analysers.

The B4 series of sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leak-proof housing is moulded with a colour coded top for ease of identification.

 

PERFORMANCE

Sensitivity Response time

nA/ppm at 2ppm CO

t90 (s) from zero to 10ppm CO

420 to 650

< 25

 

Zero current

nA in zero air at 20°C

+30 to -130

 

Noise*

±2 standard deviations (ppb equivalent)

4

 

Range

ppm limit of performance warranty

1000

 

Linearity

ppb CO error at full scale, linear at zero, 500ppm CO

20 to 35

 

Overgas limit

maximum ppm for stable response to gas pulse

2000

LIFETIME

Zero drift

ppb equivalent change/year in lab air

< ±100

 

Sensitivity drift

% change/year in lab air, monthly test

< 10

 

Operating life

months until 50% original signal (24 month warranted)

> 36

ENVIRONMENTAL

Sensitivity @ -20°C

(% output @ -20°C/output @ 20°C) @ 5ppm CO

40 to 70

 

Sensitivity @ 50°C  

(% output @ 50°C/output @ 20°C) @ 5ppm CO

110 to 125

 

Zero @ -20°C

nA

-30 to +30

 

Zero @ 50°C

nA

-50 to -200

CROSS SENSITIVITY

 

 

 

 

Filter capacity 

ppm·hrs                         H2S

250,000

 

H2S sensitivity

% measured gas @ 5ppm H2S

< 1

 

NO2 sensitivity

% measured gas @ 5ppm NO2

< 1

 

Cl2 sensitivity

% measured gas @ 5ppm Cl2

< 1

 

NO  sensitivity

% measured gas @ 5ppm NO

< -3

 

SO2 H2sensitivity sensitivity

% measured gas @ 5ppm SO2

% measured gas @ 100ppm H2 at 20oC

< 0.1

< 10

 

C2H4 sensitivity NH3  sensitivity

% measured gas @ 100ppm C2H4

% measured gas @ 20ppm NH3

< 1

< 0.1

KEY SPECIFICATIONS

Temperature range  °C range

-30 to 50

 

Pressure range       kPa

80 to 120

 

Humidity range % rh continuous

15 to 90

 

Storage period months @ 3 to 20°C (stored in sealed pot)

6

 

Load resistor W(ISB circuit is recommended)

33 to 100

 

Weight  g

< 13

 

Sản phẩm khác