KBSG- /10(6)

Model: KBSG- /10(6)

This series mine explosion-proof type transformer is applicable in underground coal mines of three-phase indirect neutral-point earthing with explosive and dangerous gas(methane) and coal dust, and it is used to change the power supply of 10kV , 6kV into low-voltage


1. Function
This series mine explosion-proof type transformer is applicable in underground coal mines
of three-phase indirect neutral-point earthing with explosive and dangerous gas(methane)
and coal dust, and it is used to change the power supply of 10kV , 6kV into low-voltage
power supply of 3450(3300)V , 1200(1140)V , 693(1660)V , 400(1380)V , which are required in
the coal mine. When the dry type transformer is used alone as mining explosion-proof dry
type transformer , it can cut off lead-in wire of high-voltage power supply by pressing
emergency button in emergent situation.

2. Model


3. Characteristics
3.1 It realizes protection by cutting off high voltage side switch when fault like short, loss of
phase, over temperature in transformer of mobile substation or fault like overload,
short circuit, electric leakage, leakafe lockout, over voltage , under voltage etc in power
distribution system happens.
3.2 Standard RS485/232 communication interface for high-low voltage switch.
3.3 Users can select high voltage load switch and low voltage vacuum feeder switch and
equip them on high or low voltage side of the transformer .

Sản phẩm khác

  • Aptomat phòng nổ KBZ-400(200)/1140(660)

    Aptomat phòng nổ KBZ-400(200)/1140(660)

    KBZ-400(200)/1140(660)

    This mine explosion-proof type vacuum feeder switch is mainly used as main switch or branch switch in AC 50Hz power distribution system of indirect neutral-point earthing with voltage of 1140V or 660V and current of 400A or 200A
  • BP J-400(250, 110)/1140(660)

    BP J-400(250, 110)/1140(660)

    BP J-400(250, 110)/1140(660)

    BPJ-400(250,110)/1140(660) mine flame-proof and intrinsically safe AC frequency converter is used in underground mines with explosive gas (methane) and coal dust. Main spare parts such as IGB T, filter capacitor, control core adopt imported brands to ensure reliable longtime operation. This series adopt vector control technique with perfect motor protection and good
  • Aptomat phòng nổ KBZ-400(200)

    Aptomat phòng nổ KBZ-400(200)

    KBZ-400(200)

    This mine explosion-proof type vacuum feeder switch is mainly used as main switch or branch switch in AC 50Hz power distribution system of indirect neutral-point earthing with voltage of 1140V or 660V and current of 400A or 200A in underground coal mines with
  • KBZ9-400(200)/1140(660)

    KBZ9-400(200)/1140(660)

    KBZ9-400(200)/1140(660)

    This mine explosion-proof type vacuum feeder switch is mainly used as main switch or branch switch in AC 50Hz power distribution system of indirect neutral-point earthing with voltage of 1140V or 660V and current of 400A or 200A
  • ZBZ-10.0(8.0,4.0,2.5)/1140(660,380)M

    ZBZ-10.0(8.0,4.0,2.5)/1140(660,380)M

    ZBZ-10.0(8.0,4.0,2.5)/1140(660,380)M

    This mine explosion-proof type integrated protective device is applicable in underground coal mines with explosive and dangerous gas(methane)and coal dust, and it is used as power control for illumination and signal load.
  • QBZ-120/660(380)(II)

    QBZ-120/660(380)(II)

    QBZ-120/660(380)(II)

    This series mine explosion-proof type vacuum electromagnetic starter is applicable in AC 50Hz distribution system of three-phase indirect neutral-point earthing with rated voltage of 1140V ,660V or 380V in underground coal mines with explosive and dangerous