Enclosure |
Weatherproof, chemical resistant, RFI / EMI coated high impact polycarbonate-PBT blend. Can operate in 2.0” of water without leakage. Ergonomically balanced with rugged top mounted handle. Water & dust resistant equivalent to IP64. |
Dimensions |
9.5” L x 5.25” W x 5.875” H |
Weight |
3.8 Lbs (standard 4 gas with batteries) |
Detection Principle |
Catalytic combustion, electrochemical cell, galvanic cell, infrared, photo ionization detector, and thermal conductivity. |
Sensor Life |
2 Years under normal conditions. |
Sampling Method |
Powerful, long-life pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH |
Display |
3 display modes: display all gases, large font-autoscroll, or large font-manual scroll. Polyurethane protected overlay. Backlight, illuminates for alarms and by demand with adjustable time. |
Language |
Readout can display in 5 languages (English, French, German, Italian, or Spanish. |
Alarms |
2 Alarms per channel plus TWA and STEL alarms for toxics. The two alarms are fully adjustable for levels, latching or self reset, and silenceable. |
Alarm Method |
Buzzer 95 dB at 30 cm, four high intensity LED’s. |
Controls |
4 External glove friendly push buttons for operation, demand zero, and autocalibration. Buttons also access LEL/ppm, alarm silence, peak hold, TWA/STEL values, battery status, conversion factors, and many other features. |
Continuous Operation |
At 70°F, 16 hours using alkaline batteries, or 18 hours using Ni-MH. |
Power Source |
4 Alkaline or Ni-MH, size C batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines). |
Operating Temp. & Humidity |
-20°C to 50°C (-4°F to 122°F), 0 to 95% RH, non-condensing. |
Response Time |
30 Seconds to 90% (for most gases) using standard 5 ft hose. |
Safety Rating |
Intrinsically Safe, Class I Groups A, B, C, D.Approvals: CSA / CE |
Standard Accessories |
Shoulder strap, alkaline batteries, hydrophobic probe, and 5 foot hose, internal hydrophobic filter |
Optional Accessories |
- Dilution fitting (50/50)
- Ni-MH batteries
- Battery charger, 115 VAC, 220 VAC, or 12 VDC (charge time 4 hours) with continuous operation function
- Extension hoses
|